The Dalekovod company in Zagreb possesses type attests for its own assortment of products, the site includes examples of standardized attests. If you should request insight into documentation, please refer to the Dalekovod-Laboratory.
| No.: | Product: | Type Attest/Report: | Attest No./Report: | Issued by: | Date: |
|---|---|---|---|---|---|
| 1 | One-sided safety fence JDOT/2 – column spacing 2m level of increased durability H1.pdf (177kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-098/07 | IGH, Zagreb | 16/07/2007 |
| 2 | Double-sided safety fence DDOT/4 – column spacing 4m level of increased durability H1.pdf (194kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-099/07 | IGH, Zagreb | 16/07/2007 |
| 3 | 2xOne-sided safety fence 2xJDOT/2 – spacing between columns 2 m level of increased durability H2.pdf (197kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-100/07 | IGH, Zagreb | 16/07/2007 |
| 4 | 2xOne-sided safety fence on bridge, column spacing 2m 2xJDOO/2 level of increased durabilitiy H2.pdf (213kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-097/07 | IGH, Zagreb | 12/07/2007 |
| 5 | 2xTwo-sided safety fence 2xJDOO/2, column spacing 2m level of increased durabilitiy H2.pdf (199kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-101/07 | IGH, Zagreb | 16/07/2007 |
| 6 | 3xOne-sided safety fence on bridge, column spacing 1.33m 3xJDOO/1.33 – level of increased durability H3.pdf (201kB) | Certificate of compliance based on HRN EN 1317-1:2001 and HRN EN 1317-2:2001 | 25-102/07 | IGH, Zagreb | 16/07/2007 |
| 7 | Vibration muffler Stockbridge type catalogue no. 66.17.90.6.pdf (59kB) | Type approval | 04/00105 | Lloyd's Register EMEA, London office | 16/11/2004 |
| 8 | Light Pole CRS 2B-7-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-339/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 9 | Light Pole CRS 2B-8-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-335/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 10 | Light Pole CRS 2B-9-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-331/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 11 | Light Pole CRS 2B-10-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-327/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 12 | Light Pole CRS 2B-11-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-323/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 13 | Light Pole CRS 2B-12-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-319/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 14 | Light Pole CRS 2B-7-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-315/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 15 | Light Pole CRS 2B-8-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-311/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 16 | Light Pole CRS 2B-9-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-307/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 17 | Light Pole CRS 2B-10-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-303/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 18 | Light Pole CRS 2B-11-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-299/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 19 | Light Pole CRS 2B-12-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-295/04 | Faculty of Civil Engineering in Zagreb | 15/10/2004 |
| 20 | Light Pole SUN 16N-1 | Report on testing trial loading of load-bearing steel structures for light poles | 25-031/04 | IGH, Zagreb | 11/01/2004 |
| 21 | Light Pole SUN 24 Z-1 | Report on testing trial loading of load-bearing steel structures for light poles | 25-033/04 | IGH, Zagreb | srpanj, 2004. |
| 22 | Light Pole SUN 16P-1 | Report on testing trial loading of load-bearing steel structures for light poles | 25-032/04 | IGH, Zagreb | 11/01/2004 |
| 23 | Light Pole SUN 14N-1 | Report on testing trial loading of load-bearing steel structures for light poles | 25-030/04 | IGH, Zagreb | 11/01/2004 |
| 24 | Light Pole SUN 16P-3 | Report on testing trial loading of load-bearing steel structures for light poles | 25-1077b/03 | IGH, Zagreb | 13/11/2003 |
| 25 | Light Poles SUN 14P-3, SUN 16P-3, SUN 16Z-3, SUN 24W-3 | Report on testing trial loading of load-bearing steel structures for light poles | 25-1077/03 | IGH, Zagreb | 13/11/2003 |
| 26 | Light Pole SUN 24W-3 | Report on testing trial loading of load-bearing steel structures for light poles | 25-1077d/03 | IGH, Zagreb | 13/11/2003 |
| 27 | Light Pole SUN 16Z-3 | Report on testing trial loading of load-bearing steel structures for light poles | 25-1077c/03 | IGH, Zagreb | 13/11/2003 |
| 28 | Light Pole SUN 14P-3 | Report on testing trial loading of load-bearing steel structures for light poles | 25-1077a/03 | IGH, Zagreb | 13/11/2003 |
| 29 | Light Pole KORS 2B-1100-1 | Report on testing trial loading of load-bearing steel structures for light poles | 25-029/04 | IGH, Zagreb | 11/01/2004 |
| 30 | Light Pole KORS 2B-900-1(2) | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-72/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 31 | Light Pole KORS 2B-1100-1(2) | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-70/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 32 | Light Pole KORS 1B-300 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-78/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 33 | Light Pole KORS 1B-400 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 64-130-178/96 | Faculty of Civil Engineering in Zagreb | 24/06/1996 |
| 34 | Light Pole KORS 1B-500 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-77/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2007 |
| 35 | Light Pole KORS 1B-600 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 64-130-182/96 | Faculty of Civil Engineering in Zagreb | 24/06/1996 |
| 36 | Light Pole KORS 2B-700-1(2) | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-76/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 37 | Light Pole KORS 2B-700-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-75/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 38 | Light Pole KORS 2B-800-1 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-74/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 39 | Light Pole KORS 2B-800-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-73/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 40 | Light Pole KORS 2B-900-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-71/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 41 | Light Pole KORS 2B-1000-1(2) | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 64-130-186/96 | Faculty of Civil Engineering in Zagreb | 24/06/1996 |
| 42 | Light Pole KORS 2B-1000-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 64-130-1190/96 | Faculty of Civil Engineering in Zagreb | 24/06/1996 |
| 43 | Light Pole KORS 2B-1100-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-69/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 44 | Light Pole KORS 2B-1200-1(2) | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-68/2001 | Faculty of Civil Engineering in Zagreb | 12/03/2001 |
| 45 | Light Pole KORS 2B-1200-3 | Attest for testing trial loading of prototype load-bearing steel structures for lighting poles | 130-54/99 | Faculty of Civil Engineering in Zagreb | 29/03/1999 |
Copyright © 2007- 2008 Dalekovod d.d.